Switchgears in every power dimensioning
Customer specific special-display for exhaust systems with background lighting
|
Compact system for exhaust systems
- SPS with display and interface for exhaust systems incl. Background lighting
- For regulation of 2 exhaust fan's, 1 transport fan, 1 auger, 1 discharger, jiggle motor / jet cleansing
- Acknowledge button for malfunctions
- Manual mode for every motor
- Status light of malfunctions
- Safety shut down on: filter breach remaining dust monitoring), fire detection and revision door
- Motor protection for exhaust and discharge
- Cleansing timers adjustable
- Forward-/backward air
- Switchgear cabinet
- Main switch
- All timers and parameters can be changed on the display
- Password protected access on different program levels
- Fully automatic control mode of the exhaust system
- Differential pressure depended cleansing of the filters
Connection of the following sensors are possible:
- Differential pressure monitoring
- Fill level monitoring
- Rotation monitoring
- Remaining dust monitoring
- Temperature monitoring
- Vibration monitoring
- Pressure monitoring
- Spark detection / spark douse units
- Explosion/ fire-protection monitoring
|